Inper Acute 330 Syringe Pump
Remote-head infusion and withdrawal, configured for the syringe and fluid path.
Review the injection setup Set the motion for small-volume delivery. Inper Acute 330 Syringe Pump A remote pump head and touch control, configured with the syringe and stereotaxic platform. Acute 330 uses a remote pump head with a connected controller. Position the head near the delivery site and connect it by cable, separating mechanical placement from parameter control. Place the head and controller separately. Choose the syringe before setting delivery. Use the built-in syringe list and check the actual syringe. Syringe selection Mainstream brands including Hamilton are listed; match the specific model and fixing method. Brand and geometry Syringe capacity range listed in the brochure Touch-control display Place the pump head where it is needed. Original Acute 330 product image. Remote placement can shorten the fluid path to the application site. Actual dead volume depends on the syringe, needle, tubing and layout. The adjustable fixing structure secures the syringe plunger. Check the barrel, plunger and drive direction during installation and match the fixture to the selected syringe. Match the plunger to its fixing structure. Select Infuse and set rate and total volume. Check direction, units and syringe model. Infuse Advance for configured delivery Select Withdraw and configure the aspiration parameters. Check the fluid path and loading before operation. Withdraw Withdraw at the configured setting Two directions with one configuration workflow. The settings work together. Functional schematic: syringe selection, mode and delivery settings. Syringe geometry, direction, rate and total volume define the delivery. Recheck the settings and units whenever the syringe changes. Review the run in one interface. Accessory syringe-pump interface from the Acute 300 manual; values are original examples. The accessory manual shows Syringe, Mode, Rate, Total and Time. Time is calculated from the selected syringe, rate and total volume to review the planned run duration. This excerpt from the Acute 300 source material shows touch operation of the accessory syringe pump, including mode, volume, rate and running status. Confirm the interface and parameter ranges for the selected controller version. See the touch controls in use. Excerpt from the original embedded video; displayed values are demonstration settings. Set delays around the workflow. Delay settings in the accessory manual. The accessory manual lists delayed start and delayed end settings. Include waiting periods in the procedure and check the controls available in the actual controller version. Place notifications at useful points. Notification settings shown in the accessory manual. The accessory manual lists notifications at run completion, a fixed time after starting, a fixed time before ending and a progress point. Select the required notifications and check the controller version. Acute 330 can be configured with stereotaxic platforms such as Acute 300. Review positioning, pump mounting, needle and syringe connections together, while setting spatial coordinates and delivery parameters separately. Let the platform and pump do their own jobs. Review the syringe, needle and required delivery volume. Viral samples Select delivery settings against sample properties and the study plan. Receptor antagonists Define wetted materials, connection length and required volume. Other small-volume samples Match the fluid path to the sample and task. Secure the syringe barrel and plunger and connect the head and controller. Mount and connect Check the syringe model, mode, rate and total-volume units. Select and configure Load, remove air and inspect the fluid path according to the procedure. Prepare the fluid path Review direction, remaining travel and displayed settings before starting. Confirm and run From syringe selection to a pre-run check. Syringe geometry, the fluid path, liquid properties and operating conditions affect delivery. Provide the syringe model, expected rate range and total volume to help confirm a suitable configuration. Review delivery settings with the experiment. Acute 300 stereotaxic instrument Review pump mounting and spatial positioning. Auto I300 automatic implanter Review instrument and holder requirements for related implantation workflows. Configure it with positioning and implantation. Syringe capacity (brochure) 0.5 μL–1 mL; match the built-in model list Operating modes Infuse / Withdraw Drive parameters listed in the brochure 0.433 μm/min–228.97 mm/min; 3200 microsteps per lead-screw revolution Repeatability (brochure) ≤ ±0.05%; confirm applicable test conditions Pump-head dimensions (without display) 201 × 35 × 86 mm Touchscreen 4.3 inches Power supply 12 V, 1 A Parameter Value / description The drive parameters retain the values and units in the source brochure and are not a liquid-volume accuracy claim. Review the selected syringe and actual fluid path together. Interface descriptions reference the accessory syringe-pump section of the Acute 300 manual. Confirm controls and display behavior for the selected controller version. Specifications and version check Inper Acute 330 Syringe Pump — Product brochure Inper 2026.B Product Catalog Read the original product documentation. Describe the subjects, procedure, existing platform and supporting equipment so we can review the version and configuration. Configure the instrument for your experiment. Send inquiry Product selection Configuration and quotation Technical and application support