Inper Auto I300 Automatic Implantation Device

Motor-driven microimplant motion configured for target, rate, holder and instrument version.

Review the implantation setup Put advancement under motor control. Inper Auto I300 Automatic Implantation Device Set target displacement and motion rate for the microimplant. Auto I300 provides motor-driven advancement for microimplants such as electrodes, fibers, cannulas and GRIN lenses. The implanter connects to its controller and works with suitable holders and a positioning platform. An implanter and controller work together. The product image shows the implanter and needle-like tool. Select the holder for the implant dimensions, shape and fixing method. Product view Review the holder geometry Review the platform, holder and implant together, including approach direction, effective travel and surrounding clearance. Another view Review working clearance Match the holder to the implant. Check device diameter, connections and fixation. Electrodes and sensors Review holder size, mounting direction and target displacement. Fibers and cannulas Check lens dimensions, holder and platform clearance. GRIN lenses Different implants need different checks. When used with a stereotaxic instrument, review the mounting interface and holder first. The study plan and platform establish spatial coordinates, approach direction and reference position; the implanter executes the configured movement. Motorized motion needs a stable mounting setup. Establish the reference before motion. Functional schematic: holder, reference position, target and motion control. Review the implant, holder, reference position and target displacement as one setup. Match directions and units to the instrument and study plan. The brochure lists a target range of 0.001–50.000 mm, while manual V1.0.1 gives 0–20 mm for Target (D/V). Confirm the effective range and travel of the delivered version before selection and operation. Confirm the target range for the version. Make advancement rate an explicit setting. Choose motion settings for the implant, target and study plan. Set for the procedure Check interface examples against the actual version to avoid unit errors. Check the units Descent-rate range listed in the brochure Direct: descend at the configured setting. Original V1.0.1 interface example; displayed values are not recommended experimental settings. Manual V1.0.1 shows Direct mode with target, rate and calculated running time. Review mode, displacement and units before starting. Zigzag: configure down and up movements. Zigzag mode example from manual V1.0.1. The same manual shows Zigzag mode, with Down and Up settings for the two motion directions. Confirm mode availability and parameter ranges for the selected controller version. The manual calculates Running time from Target and Rate. Review duration, displacement and direction together so the planned movement is explicit. Use running time to review the motion plan. The manual provides up and down controls for position adjustment. Up and down Use the controls provided by the actual controller and its manual. Start, pause and stop Check mounting, reference, mode, target and units. Pre-run review Keep the motion controls purposeful. The manual connects the implanter cable and power cable to their corresponding rear controller ports. Check cables, connectors and power specifications, then start the instrument following the applicable manual and review the main page. Connect cables and power to their matching ports. Secure the implant in its holder and check platform mounting. Mount the implant Define the starting position and direction against the study plan. Set the reference Review mode, target, rate and calculated running time. Configure motion Follow the applicable manual and record the settings used. Run and document Prepare a movement step by step. Use a stable platform, keep connections and movement areas clean, and keep liquids out of the device. Follow the manual for dry storage and review connections and motion before returning to use. Maintain clean, dry working conditions. Acute 300 stereotaxic instrument Review the platform, reference coordinates and holders. Acute 330 syringe pump Configure the syringe and pump head for related delivery tasks. Inper Vista photometry Review fiber implantation interfaces for later recording. Plan positioning and recording together. Target range: brochure 0.001–50.000 mm Target range: manual V1.0.1 0–20 mm Descent rate (brochure) 1–50 μm/s Motion Up / down; Direct and Zigzag are interface modes shown in manual V1.0.1 Compatible platform (brochure) Stereotaxic instrument; confirm the mounting interface Dimensions (brochure) 154.5 × 35 × 70 mm Power supply (brochure) 12 V, 1 A Parameter Value / description The original documents differ by version. Confirm target range, modes and interface against the delivered instrument. Specifications and version check Inper Auto I300 Automatic Implantation Device — User manual Inper Auto I300 Automatic Implantation Device — Product brochure Inper 2026.B Product Catalog Read the original product documentation. Describe the subjects, procedure, existing platform and supporting equipment so we can review the version and configuration. Configure the instrument for your experiment. Send inquiry Product selection Configuration and quotation Technical and application support